The compressor heat exchanger (often the oil cooler or interstage/gas cooler depending on system type) removes heat generated during compression and conditions refrigerant and lubricating oil to safe operating temperatures. Its primary goals are to protect compressor life, maintain lubrication performance, stabilize refrigerant thermodynamics, and keep system discharge temperatures within design limits.
Choosing the right type depends on system capacity, available utilities, footprint and environmental conditions. Below are the common types used in HVAC compressors:
When specifying a compressor heat exchanger you must document actual operating conditions, not just nominal capacity. The critical parameters are refrigerant/oil flow rates, inlet/outlet temperatures, allowable pressure drop, maximum working pressures, fluid chemistry (compatibility), fouling factors, and ambient or cooling-water temperature.
Provide: expected heat load (kW or BTU/h) from the compressor, source and sink fluid properties, allowable approach temperatures (ΔTmin), and any transient or intermittent operation that will affect mean temperatures and sizing.
State required materials (stainless steel, copper, carbon steel), flange standards, access for cleaning, and whether the exchanger must be replaceable or field-cleanable. These affect life-cycle cost and downtime.
This example shows how to calculate the cooling-water flow rate required to absorb compressor heat. Use the energy balance Q = ṁ · c · ΔT, where Q is heat duty (W), ṁ is mass flow (kg/s), c is specific heat (J/kg·K), and ΔT is allowable temperature rise (°C).
Example numbers: assume compressor heat duty Q = 50,000 W (50 kW), cooling medium is water with c = 4184 J/kg·K, and allowable ΔT = 10 °C.
Calculation steps:
When comparing options, evaluate overall heat transfer coefficient (U), required surface area (A) via Q = U·A·LMTD, pressure drop on both sides, approach temperature (how close the cold fluid can get to hot fluid), and fouling resistance. A lower approach temperature generally means larger A or higher U.
Mount the exchanger for good drainage (oil coolers must not trap oil). Provide isolation valves and bypasses for cleaning and service. Include temperature and pressure instrumentation upstream and downstream for both circuits to monitor performance. For plate exchangers, include a method for safe gasket replacement or brazed-plate replacement procedures in documentation.
Regular inspections extend life and preserve performance. Recommended practices include a quarterly visual inspection, monthly monitoring of temperature differentials, periodic cleaning of air side fins or mechanical/chemical cleaning of water-side surfaces, and oil analysis to detect elevated temperatures or contaminants that can accelerate fouling.
Symptoms, likely causes, and first-action steps:
When retrofitting older compressors, consider replacing small, inefficient air-cooled exchangers with plate or shell-and-tube units if space and utilities permit. Upgrades that reduce approach temperatures or lower fan/pump energy consumption can pay back quickly on large systems. Always validate mechanical compatibility and refrigerant/oil compatibility when changing exchanger materials or configuration.
| Type | Typical capacity range | Advantages | Limitations |
|---|---|---|---|
| Air-cooled finned-tube | Small–Medium | Simple, low water use, lower initial cost | Large footprint, poorer performance in high ambient |
| Water-cooled shell-and-tube | Medium–Large | High heat duty per footprint, robust | Needs tower/plant, more complex maintenance |
| Plate (brazed/gasketed) | Small–Large (compact) | Very compact, high U, easy to replace or service (gasketed) | Sensitivity to dirty fluids (gasketed), brazed not serviceable |
| Integral in-package oil cooler | Small | Compact, minimal piping | Limited capacity, hard to service |
For reliable compressor heat exchanger performance: collect accurate operating data, choose the exchanger type to match utilities and space, size using heat duty and allowable ΔT, specify materials and fouling factors, provide for cleaning and monitoring, and follow a disciplined maintenance schedule. These steps reduce downtime, preserve compressor life, and optimize overall HVAC plant efficiency.